49 research outputs found

    Surface wave control for large arrays of microwave kinetic inductance detectors

    Get PDF
    Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the ∼−30\sim-30 dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor >>10. With the on-chip stray light absorber the point source response is close to simulations down to the ∼−35\sim-35 dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.Comment: accepted for publication in IEEE Transactions on Terahertz Science and Technolog

    Eliminating stray radiation inside large area imaging arrays

    Full text link
    With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.Comment: arXiv admin note: substantial text overlap with arXiv:1707.0214

    Proof-of-Concept Demonstration of Vector Beam Pattern Measurements of Kinetic Inductance Detectors

    Get PDF
    We present results from the first vector beam pattern measurement ofmicrowave kinetic inductance detectors (MKIDs). Vector beam patterns require sampling of the E-field of the receiver in both amplitude and phase. MKIDs are inherently direct detectors and have no phase response to incoming radiation. We map the amplitude and phase patterns of the detector beam profile by adapting a two-source heterodyne technique. Our testing strategy recovers the phase information by creating a reference signal to trigger data acquisition. The reference is generated by mixing the slightly offset low-frequency signals from the output of the two synthesizers used to drive the submillimeter sources. The key requirement is that the time-series record always begins at the same set phase of the reference signal. As the source probe is scanned within the receiver beam, the wavefront propagation phase of the receiver changes and causes a phase offset between the detector output and reference signals. We demonstrated this technique on the central pixel of a test array operating at 350 GHz. This methodology will enable vector beam pattern measurements to be performed on direct detectors, which have distinct advantages reducing systematic sources of error, allowing beam propagation, and removing the far-field measurement requirement such that complicated optical systems can be measured at a point that is easily accessible, including the near field

    An Ultra-Wideband Leaky Lens Antenna for Broadband Spectroscopic Imaging Applications

    Full text link
    We present the design, fabrication and characterisation of a broadband leaky lens antenna for broadband, spectroscopic imaging applications. The antenna is designed for operation in the 300-900 GHz band. We integrate the antenna directly into an Al-NbTiN hybrid MKID to measure the beam pattern and absolute coupling efficiency at three frequency bands centred around 350, 650 and 850 GHz, covering the full antenna band. We find an aperture efficiency ηap≈0.4\eta_{ap} \approx 0.4 over the whole frequency band, limited by lens reflections. We find a good match with simulations for both the patterns and efficiency, demonstrating a 1:3 bandwidth in the sub-mm wavelength range for future on-chip spectrometers.Comment: Accepted for Publication at IEEE Transactions on Antennas and Propagatio

    Resolving Power of Visible to Near-Infrared Hybrid β\beta-Ta/NbTiN Kinetic Inductance Detectors

    Full text link
    Kinetic Inductance Detectors (KIDs) are superconducting energy-resolving detectors, sensitive to single photons from the near-infrared to ultraviolet. We study a hybrid KID design consisting of a beta phase tantalum (β\beta-Ta) inductor and a NbTiN interdigitated capacitor (IDC). The devices show an average intrinsic quality factor QiQ_i of 4.3×105\times10^5 ±\pm 1.3 ×105\times10^5. To increase the power captured by the light sensitive inductor, we 3D-print an array of 150×\times150 μ\mum resin micro lenses on the backside of the sapphire substrate. The shape deviation between design and printed lenses is smaller than 1μ\mum, and the alignment accuracy of this process is δx=+5.8±0.5\delta_x = +5.8 \pm 0.5 μ\mum and δy=+8.3±3.3\delta_y = +8.3 \pm 3.3 μ\mum. We measure a resolving power for 1545-402 nm that is limited to 4.9 by saturation in the KID's phase response. We can model the saturation in the phase response with the evolution of the number of quasiparticles generated by a photon event. An alternative coordinate system that has a linear response raises the resolving power to 5.9 at 402 nm. We verify the measured resolving power with a two-line measurement using a laser source and a monochromator. We discuss several improvements that can be made to the devices on a route towards KID arrays with high resolving powers.Comment: 11 pages, 9 Figues, Journal Pape

    Factors associated with pastoral community knowledge and occurrence of mycobacterial infections in human-animal interface areas of Nakasongola and Mubende districts, Uganda

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Nontuberculous mycobacteria (NTM) are emerging opportunistic pathogens whose role in human and animal disease is increasingly being recognized. Major concerns are their role as opportunistic pathogens in HIV/AIDS infections. The role of open natural water sources as source and livestock/wildlife as reservoirs of infections to man are well documented. This presents a health challenge to the pastoral systems in Africa that rely mostly on open natural water sources to meet livestock and human needs. Recent study in the pastoral areas of Uganda showed infections with same genotypes of NTM in pastoralists and their livestock. The aim of this study was to determine the environmental, animal husbandry and socio-demographic factors associated with occurrence and the pastoral community knowledge of mycobacterial infections at the human-environment-livestock/wildlife interface (HELI) areas in pastoral ecosystems of Uganda.</p> <p>Methods</p> <p>Two hundred and fifty three (253) individuals were subjected to a questionnaire survey across the study districts of Nakasongola and Mubende. Data were analyzed using descriptive statistics and multivariable logistic regression analysis.</p> <p>Results</p> <p>Humans sharing of the water sources with wild animals from the forest compared to savannah ecosystem (OR = 3.3), the tribe of herding pastoral community (OR = 7.9), number of rooms present in household (3-5 vs. 1-2 rooms) (OR = 3.3) were the socio-demographic factors that influenced the level of knowledge on mycobacterial infections among the pastoral communities. Tribe (OR = 6.4), use of spring vs. stream water for domestic use (OR = 4.5), presence of sediments in household water receptacle (OR = 2.32), non separation of water containers for drinking and domestic use (OR = 2.46), sharing of drinking water sources with wild animals (OR = 2.1), duration of involvement of >5 yrs in cattle keeping (OR = 3.7) and distance of household to animal night shelters (>20 meters) (OR = 3.8) were significant socio-demographic factors associated with the risk of occurrence of mycobacterioses among the pastoral communities in Uganda.</p> <p>Conclusion</p> <p>The socio-demographic, environmental and household related factors influence the risk of occurrence as well as pastoralists' knowledge of mycobacterial infections in the pastoral households at the human-environment-livestock/wildlife pastoral interface areas of Uganda.</p

    First light demonstration of the integrated superconducting spectrometer

    Full text link
    Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths (≥\geq1 octave) and numbers of spatial pixels (>10210^2). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of F/ΔF∼380F/\Delta F \sim 380. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to ∼\sim1.1 THz. The miniature chip footprint of a few cm2\mathrm{cm^2} allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.Comment: Published in Nature Astronomy. SharedIt Link to the full published paper: https://rdcu.be/bM2F

    Epitaxial Growth and Processing of Compound Semiconductors

    Get PDF
    Contains an introduction and reports on three research projects.MIT Lincoln LaboratoryU.S. Air Force - Office of Scientific Research Grant F49620-96-1-0126National Science Foundation Grant DMR 94-00334Joint Services Electronics Progra
    corecore